To power the device, use a power supply with an output voltage compatible with the devicespecification. The power supply should by connected using a connection terminal (located under the device housing cover) or a DC-JACK connector (for the Ethernet version - located on the housing).
DiOne | Description | Comments |
---|---|---|
LEDs | Red LED - power supply indicator Green LED - data transmission indicator | |
Sensor | The exact size and location of the sensor depends on device version | |
Signal and electrical connection | TB: V - power supply 11,5…27 VDC TB: GND - GND (digital and analog) TB: A, B - RS-485 interface TB: A*, B* - n/a DiOne devices | |
LCD | Configurable display with backlight |
Each DiOne transmitter has two LEDs that indicate the device's operating status. LED function description:
DiOne | Description | Comments |
---|---|---|
Red LED (L1) | ON when the transducer power supply is connected (continuous light) | |
Green LED (L2) | On when data is being transmitted (blinking light) |
Be careful when connecting the device. Incorrect connection may damage the device and/or damage other devices that are connected to the device or system.
All connections must be made when the power is off!