Si-C50J2P1

    • Powerful Microprocessor
    • Functionally Programmable
    • Fast Configurations
    • Modbus Interface
    • Wide range of supply voltage
    • Additional options available

    SiOne can be humidity, temperature, barometric pressure, differentia pressure, carbon dioxide (CO2), volatile organic compounds (VOC), particulate matter (PM) and/or Analog signal transmitters (it depends on model). The SiOne line combined with an internal and/or external sensors provide state-of-the-art functionality. Various models are available including wall, duct or remote sensors. SiOne is introducing powerful programming capabilities. Settings of the device can be modified through USB programming unit, PC software or Modbus interface. Modbus RTU baud rate, Modbus RTU address and type of Analog outputs can be fast changed by configuration jumpers.

    Schemat połączenia SiOne

     

    ( 1 ) – RS-485 interface (Modbus RTU) or Industrial Ethernet (Modbus TCP)
    ( 2 ) – programmable relay output On/Off (option)
    ( 3 ) – programmable (up to 3) Analog outputs: 0…5 V, 0…10 V, 0…20 mA or 4…20 mA (option)

     

    SiOne transmitters offers Fieldbus (RS-485 – Modbus RTU) or Industrial Ethernet (Modbus TCP) interfaces. The SiOne line can provide up to three fully programmable and scalable Analog outputs (types of output: 0…5 V, 0…10 V, 0…20 mA or 4…20 mA). Analog output can be modified by configurations jumpers, Modbus interface or USB programming unit. SiOne transmitter with relay output can be used as simple binary sensor (pressostat, hygrostat, thermostat, CO2-stat, …). Threshold and hysteresis of output can be also modified by Modbus or programming unit.

    Technical drawing

    All dimension in mm. This drawing is for informational purposes only. The manufacturer reserves the right to make changes in the product dimensions without prior notice.

Kod produktu

Si-C50J2P1

Typ urządzenia
Mierzone parametry
Zakres pomiarowy
Dokładność (maks.)

±200 ppm ±10% (% RD)

Dodatkowe opcje

Typ sensora
Filtr sensora

Zasilanie
Interfejs

RS-485 (Modbus RTU)

Wyjścia analogowe
Wyjścia analogowe - typ
Wyjścia analogowe - rozdzielczość
Wyjścia binarne
Wyjścia binarne - parametry
Przyłącze elektryczne
Diody serwisowe

2x LED

Wyświetlacz
Pamięć - rejestrowane dane
Pamięć - typ
Pamięć - pojemność
Pamięć - częstotliwość zapisu
Parametryzacja
Stopień ochrony
Temperatura pracy
Wilgotność pracy
Typ obudowy
Materiał obudowy
Wymiary obudowy
W komplecie
Częstotliwość pomiaru

0.25 Hz (CO2)